CCRHY - IMRON 5000 POLYURETHANE ENAMELS, 8685S

  • MSDS: CCRHY
  • Manufacturer: E I DUPONT DE NEMOURS AND CO
  • Product Name: IMRON 5000 POLYURETHANE ENAMELS, 8685S
  • National Stock Number: 8010-00N074007
Product Identification

Product ID:IMRON 5000 POLYURETHANE ENAMELS, 8685S
MSDS Date:01/01/1995
FSC:8010
NIIN:00N074007
MSDS Number: CCRHY

Responsible Party
E I DUPONT DE NEMOURS & CO
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Preparer: T.R. LOUER

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

76

CAS: 141-78-6

RTECS: AH5425000

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHANOL, 2-BUTOXY-, ACETATE; (ETHYLENE GLYCOL MONOBUTYL

CAS: 112-07-2

RTECS: KJ8925000

OSHA PEL N/K

ACGIH TLV: N/K


2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 9%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM;300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOCYANATE SHOULD NOT USE/BE EXPOS TO THIS PROD.

RTECS: 9999999ZZ


FOLLOW RESPIRATOR MFR'S DIRECTIONS FOR RESPIRATOR

RTECS: 9999999ZZ


PRLNG & RPTD HIGH EXPOS

RTECS: 9999999ZZ


WHITE BLOOD CELLS; FATTY DEGENERATION, CLOUDY SWELL &

RTECS: 9999999ZZ


CAN BE ABSORBED THRU SKIN IN

RTECS: 9999999ZZ


HIGH CONCS

RTECS: 9999999ZZ


ETHYL KETONE HAS BEEN DEMONSTRATED TO POTENTIATE

RTECS: 9999999ZZ


CAUSED BY EITHER N-HEXANE/METHYL N-BUTYL KETONE. MEK

RTECS: 9999999ZZ


PERIPHERAL NEUROPATHY. LIQ SPLASHES IN EYE MAY RSLT

RTECS: 9999999ZZ


DOSE-RELATED ADVERSE EFTS ON THE CNS, HEMATOPOIETIC

RTECS: 9999999ZZ


ETHYLENE GLYCOL MONOBUTYL ETHER ACETATE (EGBEA).

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:GI DISTRESS. INHAL:MAY CAUSE
NOSE & THROAT IRRIT. RPTD & PRLNG OVEREXP TO SOLVS MAY LEAD TO PERM
BRAIN & NERV SYS DMG. EYE WATERING, HDCHS NAUS, DIZZ & LOSS OF
COORD ARE SIGNS THAT SOLV LEVELS ARE TOO HIGH. EXPOS TO
ISOCYANATES MAY CAUSE RESP SENSIT. THIS EFT MAY BE PERM. THIS EFT
MAY BE DELAYED(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:FOR SEVERAL HRS AFTER EXPOS. RPTD
OVEREXP TO ISOCYANATES MAY CAUSE DECR IN LUNG FUNC WHICH MAY BE
PERM. INDIVIDUALS W/BRTHG PROBS/PRIOR RXN TO ISOCYANATES MUST NOT
BE EXPOS TO VAPS/SPRAY MIST S OF THIS PROD. EYE CONT:MAY CAUSE
IRRIT/BURNING. SKIN CONT:RPTD/PRLNG LIQ CONT MAY CAUSE IRRIT
W/DISCOMFORT & (ING 7)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD & HAVE NAMES OF INGREDIENTS AVAILABLE.
INHAL:REMOVE TO FRESH AIR. IF BREATHING DIFFICULTY PERSISTS, OR
OCCURS LATER, CONSULT MD. EYES:IMMEDIATELY FLUSH W/PLENTY OF WATER
FOR AT LEAST 15 MINUTES; CALL MD. SKIN:WASH W/SOAP & WATER. IF
IRRITATION OCCURS, CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:-73F,-58C
Lower Limits:0.9%
Upper Limits:23%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FLASH POINT, EMITS
FLAMMABLE VAPORS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLO. FINE
MISTS/SPRAYS MAY BE FLAMM AT TEMPS BELOW FLASH POINT.

Accidental Release

Spill Release Procedures:DO NOT BREATHE VAPS. DO NOT GET IN EYES/ON
SKIN. WEAR A NIOSH APPRVD POS PRESS SUPPLIED AIR VAP/PARTICULATE
RESP (TC-19C), EYE PROT, GLOVES & PROT MATL. REMOVE SOURCES OF
IGNIT. ABSORB W/INERT MATL. R EMOVE SOURCES OF IGNIT. ABSORB
W/INERT (SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OSHA STORAGE:IB. DO NOT BREATHE
VAPORS/MISTS. OBSERVE LABEL PRECAUTIONS. KEEP AWAY FROM HEAT,
SPARKS & FLAME. CLOSE CONTAINER AFTER EACH USE.
Other Precautions:FLAMMABLE LIQUID. GROUND CONTAINERS WHEN POURING. DO
NOT STORE ABOVE 120F. DO NOT SAND, FLAME CUT, BRAZE OR WELD DRY
COATING W/OUT A NIOSH APPROVED RESPIRATOR OR APPROPRIATE
VENTILATION.

Exposure Controls

Respiratory Protection:WEAR A NIOSH APPRVD POS PRESS SUPPLIED AIR RESP
(TC-19C) WHILE MIXING ACTIVATOR W/ANY PAINT/CLEAR ENAMEL, DURING
APPLICATION & UNTIL ALL VAPS & SPRAY MISTS ARE EXHAUSTED.
INDIVIDUALS W/HISTORY OF LUNG /BRTHG PROBS/PRIOR RXN TO (ING 5)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . COVERALLS ARE RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING & BEFORE EATING
OR SMOKING.
Supplemental Safety and Health
SPILL PROC:MATL. VENT AREA. POUR LIQ DECONTAMINATE SOLN OVER SPILL &
ALLOW TO SIT 10 MINS, MIN. TYPICAL DECONTAM SOLNS ARE:20%
SURFACTANTS (TERGITOL TMN 10); 80% WATER; 0-10% AMMONIA; 2-5%
DETERGENT; BALANCE WATER. THIS PROC CAN GENERATE PRESS. DO NOT
SEAL CNTNR. AFTER 48 HRS, CNTNR MAY BE SEALED & DISPOSED OF.

Chemical Properties

Boiling Pt:B.P. Text:>135F,>57C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Volatile Org Content %:8
Spec Gravity:0.9
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2, SMOKE, OXIDES OF HEAVY
METALS IN INGREDIENTS.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL I/A/W FEDERAL, STATE &
LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED CONTAINERS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.